4.6.1.1 Boom Frame Roll Sensor

Mounting

1. Use the supplied hardware to mount

the boom frame roll sensor (E04) as
shown in Figure 20.

When mounting the boom frame roll
sensor follow these guidelines:

a) To prevent bending the bracket, ensure

bolts are placed as close together as
possible (minimize C in Figure 20).

b) Be sure to use the roll sensor without

the temperature probe (E04).

c) When the boom is centered (not rolled

over) the roll sensor should be level
with respect to the sprayer chassis.

d) It is best to mount the roll sensor to

the left hand trapeze link (when looking
from the rear of the sprayer).

e) The roll sensor AMP (circular)

connector MUST exit towards the
right hand wing
(when looking from
the rear of the sprayer).

2. Cable-tie the sensor connector to the

frame with enough slack to allow the
link to rotate.

Make sure the bracket does not

collide with any parts of the
sprayer when the boom rotates.

Also ensure there is enough slack
to allow the roll sensor to rotate.

Figure 20: Boom Frame Roll Sensor

Mounted to a Trapeze Link