WARNING: Hazard of Electric Shock. Disconnect all
power before installing heater.

1. Locate on vertical wall with length of heater positioned hori-

zontally.

2. When selecting a mounting location, the following minimum

distances must be observed to insure proper operation.

A. Six (6”) inches from bottom of heater to floor.
B. One (1”) inch from wall or other obstruction to the right or

left side of heater.

3. Do not mount heater in a recess, since such mounting interferes

with free air circulation, increases temperatures and prevents
proper thermostat operation.

4. Mount the rear panel assembly of the heater to the wall using

the

11

/

32

” dia. holes (bolts to be supplied by customer).

5. Install the perforated cover by hooking the top edge of the

cover over the top edge of rear panel.

6. Attach the bottom lip of the perforated cover to the wall using

the

1

/

4

-20x1” tamper proof screws.

7. On lower cover assembly connect wires T1-T1 and T2-T2 with

wire nuts provided. Install cover assembly with (2) 10-32x

1

/

2

and (1)

1

/

4

-20x1” tamper proof screws. Use special magnetic

bits provided. (Use standard

5

/

16

socket or variable speed drill

when attaching screws.

8. Wire power lines to pigtail leads marked L1 and L2. Connect

ground wire to the green pigtail lead.

9. Adjust thermostat to the desired setting. Install top access

cover with (4) 10-32x

1

/

2

tamper proof screws using spanner

tool bits provided.

MOUNTING

WARNING: Hazard of Electrical Shock. Any installa-
tion involving electric heaters must be grounded to
earth to eliminate shock hazard.

Note: Electrical wiring is to be in accordance with National
Electrical Code and local codes using at least 75°C (167°) type
RH, THW or equivalent insulated wire.

1. Electrical wiring must be brought into heater through

13

/

32

” dia.

hole located in the rear panel.

2. Grounding conductor with green insulation must be connected

to the green pigtail lead.

3. Make the proper connections using the appropriate wiring dia-

gram below. Use diagram A for 120 and 277V heaters and use
diagram B for 208 and 240V heaters. These diagrams apply to
all size heaters.

WIRING

White Wire

Heating

Element

Auto
Cutout

T'Stat

Black Wire

Disconnect
Switch

Grd (Green)

Wire Nuts

Common

120 277V

Power

Circuit

T2

T2

T1

T1

L2

L1

Heating

Element

Auto
Cutout

Double
Pole
T'Stat

Disconnect
Switch

Wire Nuts

208 240V

Power
Circuit

Grd (Green)

T2

T1

T2

T1

L2

L1

Wiring Diagram A

Wiring Diagram B

Advertising