2 valve assembly: double acting – NORAC UC5-BC-GN01 User Manual
Page 31
Advertising

28
10.2 Valve Assembly: Double Acting
1. On a clean surface remove the plastic plugs from the block.
2. Install the 6MB-6MJ (F07) fittings into the “P” and “T” ports. Tighten to 18 ft-lbs (24 Nm).
3. Insert the two orifices (F08) into the “B” ports with the notch facing out.
4. Install the 6MB-6MJ (F07) fittings into the “B” ports. Tighten to 18 ft-lbs (24 Nm).
5. Insert the two orifices (F08) into the “A” ports with the notch facing in.
6. Install the 6MB-6MJ (F07) fittings into the “A” ports. Tighten to 18 ft-lbs (24 Nm).
Fitting F07 is a special fitting; if an additional coupler is required, contact NORAC.
Figure 31: NORAC Valve Block Details (Double Acting)