9 connecting the sensors to the canbus – NORAC UC5-BC-JD07A User Manual

Page 26

Advertising
background image



23

9 Connecting the Sensors to the CANbus

1. Fasten the 8-way coupler to the boom with cable ties. Connect cable C03 from the input

module to the 8-way coupler (E11).

2. Connect the main lift sensor to the 8-way coupler using cable C02 and a 2-way coupler

(E12). Cable C02 and item E12 may not be needed if the 8-way coupler is mounted close
enough to the main lift sensor.

3. Connect the position sensor (E06) and the active roll cylinder (H75) to the 8-way coupler

using cable C04 and a 2-way coupler (E12).

4. Connect two cables (C05) to the 8-way coupler and route along the booms to the wing

sensors. Follow existing cables and hoses to be sure the cable will not be pinched or
stretched.

5. At the sensor brackets, attach a 2-way coupler with terminator (E20) to the sprayer boom.

The 2-way coupler with terminator is the white two way coupler. Plug the sensor and the

CANbus cable into the 2-way coupler.

6. Insert the 6 pin plugs (P03) into the remaining receptacles of the 8-way coupler.

Ensure that all unused connectors are plugged with the plugs provided.

Advertising