2. Park the sprayer on level ground with no vegetation. Calibration must be performed with
the sensors “looking at” bare ground, gravel or carpet. Hard surfaces such as concrete and
asphalt are not desirable. Snow and puddled water will also cause calibration problems
3. The sprayer should be at operating RPM with the hydraulic oil at operating temperature.
13.2 System Calibration
With the system in Manual Mode, select the Settings button
(wrench).
Select the Next button (right arrow).
Select the Next button (right arrow).
Select the Setup button.
Select Automatic Setup.
Acknowledge the warning.
Select the sprayer make and model from the lists.
Then select the Check button.