17. Disconnect the connection where the flex line and steel line meet. Be sure this is the line

that connects to the gold accumulator block at the tilt cylinder.

18. Install a 6FJXR 6MJT fitting (F04) onto the steel line and then attach the flex line to the tee

fitting. Install hose H03 onto the tee fitting.

Figure 25: Tee in the “B” (Raise) Line

19. Remove the 12MB 12MB orifice fitting installed between the gold accumulator block and tilt

cylinder. Replace the fitting with the 12MB 12MB fitting (F08).

Figure 26: Fitting Between the Cylinder and Accumulator Block to be Replaced

20. Remove the accumulator from the block. Remove the 8MB 8MB fitting from the gold block.

Turn the fitting over and reinstall it into the block so the adjustable end, where the
accumulator will thread on, is facing up.

21. Install the orifice insert (F09) inside the accumulator. Reattach the accumulator with the

orifice inside.

Figure 27: Orifice Insert Installed in the Accumulator

Flex Line to

Accumulator

Steel Line

NORAC

“B” Line

Replace This

Fitting with F08

Flip This Fitting