28

11. At the accumulator, remove the existing fitting from between the hoses and accumulator

(Figure 33). Insert the 6FJXL 6MJT tee (F09) in its place.

12. Connect the 8FJ 6MJ adapter (F08) and the 8MB 8MJ orifice (F07) between the tee (F09)

and the accumulator.

Figure 33: Existing Accumulator Fitting

Figure 34: New Accumulator Fittings

Replace this

fitting with F09.

F07

F08

F09