background image

Element glows when energized,

Turn the needle-valve clockwise slowly until

it stops. This is the fully closed position.

Do not force to turn further.

Open the Needle-Valve

2 turns from the fully

closed position.

Close

Replace the plug when the

element does not glow or is
burnt out.

Glow Plug Igniter

In case of the 11 K carburetor

Set the throttle-stop screw so that the minimum

throttle opening (idle setting) is approximately

0.3-0.5mm.

In case of the 11 L carburetor

Set the throttle-stop screw so that the minimum

throttle opening (idle setting) is approximately

1.0mm.

Throttle Stop

Screw

approx

1mm

Note:

Throttle opening at idle should be checked
before fitting an air cleaner.

Pliers

Needle Valve

Open