SX981134 Conical head screw M3x8 (4x)

{

SX642403 24 kOhms 1% R0805 Resistor (2x)

{

SXS351220 22pF 1% C0805 (1x)

{

SXS644990 49,9 Ohms 1% R0805 Resistor (1x)

{

SXS641503 15 kOhms 1% R0805 Resistor (1x)

{

SX860131 Bantam mini-jack pre-wired (1x)

{

SX140002 NPN-Transistor BC 550 C

When installing an SX022270 SX-S Extension Module in an SX-S mixing console with serial-number 16585 or

lower R-64 and R-65 on the extension module operator board need to be replaced by 24kOhms 1% SMD R0805.

7.2 Procedure

On the Master Board (solder side) solder the 6 conductors of the ribbon cable(see PCB Layout)

Change Q1 (BC337) on the Masterboard with BC 550C (SX140002).

Mount the 12-pin Hirose socket in place of the last Input's 3-pin Neutrik.

Install the 6-pin Neutrik socket next to the 12-pin Hirose socket.

Install the Extension module beside the master board and connect the wires asindicated on the PCB Layout. Do

not forget to install the additional 26-pin connector on the SX-S10 ribbon cable.

SX-S 10

: Disconnect the Aux. XLR 3-pin male and replace it with SX860141,socket 1/4'' with 150mm shielded

cable and Dubox case.

SX-S 6 SX-S 8

: Remove the existing 1/4'' Jack, unsolder the connections on the Masterboard and reconnect to the

Bantam Jack with cable provided. Install the SX860141, socket 1/4'' with 150mm shielded cable and Dubox case.

Click here for Illustration of INTERNAL connections, ajustments and switches

Click here for Master Module PCB Layout

NOTE:The ribbon cable connects to the PCB (from Left to right) Yellow - Brown - Orange - Green - Red - Blue.

Connections of the 6 pole Flatcable

7.3 Optional

External Slate MIC for the Mixer's operator

Brown Cable

1

PFL-BUS-left

Connected to pin No 1 OP-7

Red Cable

2

MASTER-BUS-right

Connected to pin No 1 OP-3

Orange Cable

3

PFL-BUS-right

Connected to pin No 7 OP-7

Yellow Cable

4

Auxiliary BUS

Connected to cursor Aux potentiometer

Green Cable

5

PFL Control-CDE (sense)

Connected to point R-6/R-5/collector of
Q1

Blue Cable

6

MASTER-BUS-left

Connected to pin No 7 OP-3

Seite 16 von 22