Section 3. ET Instrumentation Installation

3-12

3)

Connect the 5-foot patch cord to the Rad Modem. Fasten the cable to the
strain relief tab with a cable tie. Connect the Rad to the PC's serial port
either directly (25 pin port) or through a 9 to 25 pin serial converter.

4)

Route the user-supplied cable from the remote splice to the surge protector.
Connect it and the 5-foot patch cord to the surge protector.

- RCV (white)

- RCV (black)

+ RCV (green)

+ RCV (red)

+ XMT (red)

+ XMT (green)

- XMT (black)

- XMT (white)

- RCV

+ RCV

+ XMT

- XMT

BLACK

RED

GREEN

WHITE

2

1

3

4

- RCV (black)

+ RCV (red)

+ XMT (green)

- XMT (white)

2

1

3

4

SRM-5A

Surge

Protector

PC

User

Supplied

Cable

Splices

ET106 ENCLOSURE

ET106 ENCLOSURE

To # 8

External Connector

Earth Ground

CAMPBELL

SCIENTIFIC LTD

SC932 - S/N E1055

QC

FIGURE 3.3-5. Short-Haul Modem Wiring Diagram

3.4 Sealing and Desiccating the Enclosure

The ET Enclosure is supplied with a desiccant pack. The desiccant maintains a
low humidity in the enclosure to minimize the chance of condensation on the
instrumentation. Desiccant should be changed when the internal ET Enclosure
humidity sensor measures 30% or higher. Install the desiccant as shown in
Figure 3.4-1. Keep unused desiccant tightly sealed in an airtight container.

1)

Take the desiccant pack out of its sealed plastic bag. Place it under the
desiccant strap just before leaving the station.

2)

Be sure to close the enclosure hasp securely. A padlock may be used on
the latch for extra security.