CITIZEN CBM-710 User Manual

Page 16

Advertising
background image

CBM-710/720 Service Manual

14

7.

Parallel Interface Circuit

This circuit conforms to the standard interface. Description will be made for each signal of interface connector as
follows. Fig. 7-1 shows the data input and print timing chart and Fig. 7-2 the parallel interface circuit diagram.

DATA (D1~D8) : 8-bit parallel signal (Positive logic)

STB

: Strobe signal for reading 8-bit data (Negative logic)

RESET

: Signal for resetting the printer (Negative logic)

ACK

: Data request signal to be output at the end of BUSY signal (Negative logic)

BUSY

: Signal for indicating if the printer is in the busy state; it goes into the busy state for H. (Positive

logic)

FAULT

: Signal to be output when the printer is in the abnormal state; at this time all control circuits in

the printer stop. (Negative logic)

PE

: Signal to be output when the print paper becomes short (Positive logic)

FG

: Frame ground

Fig. 7-1 Data Input and Print Timing Chart

Advertising