Gas fireplace insert, Gas supply pressures, Installation of remote switch for rn/rp gas valves – CFM Corporation A125 User Manual

Page 7: Adjustment of leveling bar (if required)

Advertising
background image

7

Gas Fireplace Insert

10002964

CFM106

Typical Gas Line Connection

9-29-00

1/2” Gas Supply

1/2” x 3/8” Reducer

3/8” Nipple

3/8” x 3/8” Shut

Off Valve

3/8” Nipple

3/8” Union

3/8” Nipple

CFM106

Fig. 4 Typical gas line installation.

When using copper or flex connector, use only
approved fittings. Always provide a union when
using black iron pipe so the gas line can be easily
disconnected for burner or fan servicing. See gas
specifications for pressure details and ratings.
NOTE: If flex connector is used, it must be kept inside
of the heater.

Gas Supply Pressures

This heater must be isolated from the gas supply piping
system by closing its individual manual shut-off valve
during any pressure equal to or less than 1/2 psig
(3.45kPa).
The heater and its individual shut-off valve must be
disconnected from the gas supply piping system during
any pressure testing of that system at test pressures in
excess of 1/2 psig (3.45kPa).

Installation of Remote Switch

for RN/RP Gas Valves

1. Thread wire through gas inlet opening on the right

side of fireplace. Do not cut wire or insulation on
metal edges.

2. Slide switch assembly from the back, between sub-

frame and trim, then fasten the screw. (Fig. 5)

3. For left side installation reverse switch position in

bracket and repeat Step 2. (Fig. 6)

4. Connect wiring to gas valve (Fig. 7a,b) and switch.

������
������
�����

Trim Screw

Wiring from

Millivolt Gas

Valve

On/Off Switch Assembly

FP1657

Fig. 5 Install switch between subframe and trim.

������
����������������
�����

Trim Top

Trim Left Side

Bracket Switch

Trim

Screw

Wiring

from

Millivolt

Gas

Valve

On/Off

Switch

Assembly

FP1657

Fig. 6 Left side switch installation.

TPTH

TH

TP

FP1218a

Remote switch

wiring - rocker

1/03

FP1218a

Fig. 7b ON/OFF switch wiring.

PILO

T

THTP

TP

TH

FP382a

REMOTE SWITCH WIRING - NVC

1/03

SIT Valve

Thermopile

FP382a

Fig. 7a On/Off switch or millivolt thermostat.

CAUTION: Do not wire millivolt remote wall
switch for gas fireplace to a 120 V power
supply.

Adjustment of Leveling Bar

(If Required)

1. Determine height of adjustment.
2. Loosen the four (4) screws. (Fig. 8)
3. Set bar at proper height and tighten the screws.
4. Add the two (2) extra screws to prevent any move-

ment.

NOTE: Leveling bar only applies to A132.