Intrepid ii woodburning stove, Double-wall chimney connector, Single-wall chimney connector – Vermont Casting 1990CE User Manual

Page 6: Freestanding chimney installations

Advertising
background image

6

Intrepid II Woodburning Stove

30003840

Double-wall Chimney Connector

Information on assembling and installing double-wall
connector is provided by the manufacturer of the
double-wall pipe. Follow the manufacturer’s instructions
exactly as you assemble the connector and attach it to
the stove and chimney. Using connectors and chim-
neys from the same manufacturer makes the assembly
and installation straightforward.
NOTE: For installations using double-wall con-
nectors, minimum clearances must conform to the
listed clearances on Page 9.

Single-wall Chimney Connector

Beginning at the flue collar of the stove, assemble

the chimney connector. Insert the first crimped end into
the stove’s flue collar, and
keep each crimped end
pointing toward the stove.
Using the holes in the
flue collar as guides, drill
3 mm (1/8”) holes in the
bottom of the first section
of chimney connector and
secure it to the flue collar
with three #10 x 1/2” sheet
metal screws.

Secure each joint be-

tween sections of chimney
connector, including tel-
scoping joints, with at least
three sheet metal screws.
The pre-drilled holes in
the top of each section of
chimney connector serve as guides when you drill 3 mm
(1/8”) holes in the bottom of the next section.

Secure the chimney connector to the chimney. In-

structions for various installations follow.

Be sure the installed stove and chimney connector

are correct distances from nearby combustible material.
NOTE: Special slip pipes and thimble sleeves that form
telescoping joints between sections of chimney con-
nector are available to simplify installations. They often
eliminate the need to cut individual connector sections.
Consult your local dealer about these special pieces.

Securing the Single-wall Connector to a

Prefabricated Chimney

For prefabricated chimneys, follow the installation
instructions of the chimney maker exactly as you install
the chimney. The maker of the chimney will supply the
accessories to support the chimney, either from the roof
of the house, at the ceiling of the room where the stove
is installed, or from an exterior wall.

Special adapters are available from your local dealer to
make the connection between the prefabricated chim-
ney and the chimney connector. The top of such adapt-
ers attaches directly to the chimney or to the chimney’s
ceiling support package, while the bottom of the adap-
tor is screwed to the chimney connector.
These adapters are designed so the top end will fit
outside the inner wall of the chimney, and the bottom
end will fit inside the first section of chimney connector.
When assembled in this way, any soot or creosote fall-
ing from the inner walls of the chimney will stay inside
the chimney connector.

Securing the Single-wall Connector to a

Masonry Chimney

For masonry chimneys, both freestanding and fireplace
chimneys may be used for installation of your Intrepid II.

Freestanding Chimney Installations

If the chimney connector must pass through a combus-
tible wall to reach the chimney, follow the recommenda-
tions in the Wall Pass-through section that follows.
The opening through the chimney wall to the flue (the
“breach”) must be lined with either a ceramic or metal
cylinder, called the “thimble”, which is cemented firmly
in place. The fit must be snug and the joint between the
thimble and the chimney wall must be cemented. (Fig. 4)

ST492a

Intrepid II

freestanding

installation

11/00

INTRE

PID II

Chimney

Elbow

Slip Pipe

Standard

Chimney

Connector

Flue Collar

Flue

Flue

Liner

Thimble

ST492a

Fig. 4 Chimney connection in a freestanding installation.

ST242

Chimney connector

12/13/99 djt

Fig. 3 The crimped end of
the connector points toward
stove.