Safety sensor posts, Trench for wiring, Assemble safety sensors – Chamberlain THE PROTECTOR SYSTEM 916GA User Manual

Page 2

Advertising
background image

Ins

ide Proper

ty

Metal

OR

Wood

ENTRAPMENT
Safety Sensor Posts

OPEN

Safety Sensor Posts

Inside Property

Outside Property

CLOSE

Safety Sensor Posts

Inside Property

6" (15 cm) trench for
safety sensor wires

OPEN SAFETY SENSORS

Inside Property

6" (15 cm) trench for
safety sensor wires

Out

sid

e Property

6" (15 cm) trench
for safety sensor
wires

CLOSE SAFETY SENSORS

ENTRAPMENT SAFETY SENSORS

NOTE: For ideal protection the safety sensors should be installed as close
to one another as possible with the maximum distance up to 30' (9.1 m).

To AVOID damaging gas, power or other underground utility lines,
contact underground utility locating companies BEFORE digging.

ATTENTION

AVERTISSEMENT

AVERTISSEMENT

AVERTISSEMENT

WARNING

CAUTION

CAUTION

WARNING

WARNING

PRECAUCIÓN

ADVERTENCIA

ADVERTENCIA

ADVERTENCIA

2

SAFETY SENSOR POSTS

Use a metal or treated wood post (not provided) to elevate the sensors.
Safety sensors must be installed no higher than 24" (61 cm) above the
ground.

POWER

Disconnect power and batteries to the operator.

TRENCH FOR WIRING

Before digging, contact local underground utility locating companies.

Dig a narrow trench 6" (15 cm) deep from control box to safety sensor
posts. Be careful not to damage any buried wire. Run conduit from
control box to safety sensor posts and run low voltage wire* (not
provided) through conduit.

* UL approved Class 1 or Class 3 direct burial/underground, sunlight/UV resistant 16 gauge 2-conductor/standard wire.