26

VL6C+ ™ SPOT LUMINAIRE USER MANUAL

Configure APS6 module(s):

Lamp power for the VL6C+ Spot Luminaire is provided by an APS6 power supply module installed in a Series 300
Modular Rack.

CAUTION:

Do not change mode or power setting with power applied to module.

Step

1. At face of APS6 module(s), set rotary power switch to the 700W position (Figure 2-10).

Step

2. Set mode switch to PSET for manual operation.

Step

3. Apply power to lamp by moving circuit breaker switch to the ON position.

Note: The PSET (Preset) mode enables manual control of the module. This is the normal mode of operation. The DCV
(Dimmer Control Voltage) mode operates the module with 0-10Vdc control input. This mode is only required when
using an SPC-36 controller to remotely control modules from a console.

Figure 2-10: APS6 Module

Power Up the Luminaire:

Proceed to

"Powering Up the Luminaire"

on page 28 for further operating instructions.