Progressive Industries EMS-PT50C User Manual

Page 3

Advertising
background image

Warnings

•

Do not exceed the rating on the EMS for any reason,

however, these devices are designed to be reduced down to

120V/15A, and still maintain full protection.

•

Do not modify the EMS in any way, this will void the

warranty, compromise protection, and could result in

possible shock, and/or a fire hazard.

•

It is important to always check the pedestal power outlet for

charring; this condition means that the AC receptacle is

providing a weak connection. DO NOT USE! It could

result in possible melting of the RV power plug.

•

When running extension cords from the RV to AC power,

always use a 6-gauge cable for your 240V, 50 Amp system.

Make sure that the cable is rated for outdoor use to reduce

the risk of electric shock. Small gauge cable will have a

higher resistance and will result in a voltage loss, plus it

may result in an electrical fire.

•

Whenever servicing or installing the EMS or any other AC

powered device, make sure AC power is disconnected.

•

RV wiring is different than the wiring found in homes; the

neutral and ground conductors are isolated in the RV,

unlike in a home where they are tied together at the service

panel. The reason is: homes have a bonded ground

system, whereas RV’s do not. Therefore, never bond the

neutral and ground together for any reason. This will

create a ground fault condition, and may result in electric

shock and/or a fire hazard.

•

Never

plug the EMS into an inverter.