Assembly

TORCH INSTALLATION (See Fig. 2)

1. Make sure unit is off and unplugged.

2. Feed the connectors for the torch

switch through the hole in the control
panel. These leads are to be fed up
over the polarity studs and through the
hanger on the center wall.

3. Insert the brass torch connector

through the hole in the control panel
and into the drive deck. Make sure the
connector is inserted fully into the
drive deck. Loosen the torch clamp
knob a few turns if the connector will
not insert fully. Tighten the torch
clamp knob securely after the brass
torch connector is fully inserted.

Wire Feed Arc Welder

General Safety

(Continued)

Safe Practices For Occupational And
Educational Eye And Face Protection

ANSI Standard Z87.1, from American
National Standards Institute, 1430
Broadway, New York, NY 10018

Refer to Material Safety Data Sheets and
manufacturers instructions for metals,
wire, coatings and cleaners.

Installation

LOCATION

Selecting the proper location can
significantly increase performance,
reliability and life of the arc welder.
● For best results locate welder in a

clean and dry environment. Dust
and dirt in the welder retain
moisture and increase wear of
moving parts.

● Place welder in an area with at least

twelve inches (305 mm) of ventilation
space at both the front and rear of
unit. Keep all obstructions out of this
ventilation space.

● Store welding wire in a clean, dry

location with low humidity to
prevent oxidation.

● Use a properly grounded receptacle

for the welder and ensure welder is
the only load on power supply
circuit. Refer to chart on page 1 for
correct circuit capacity.

● Use of an extension cord is not

recommended for electric arc welding
machines. Voltage drop in the
extension cord may significantly
degrade performance of the welder.

4. Connect the torch switch connectors to

the two 1/4" terminals in the center
wall. Polarity is not important. Make
sure these wires do not interfere with
the polarity studs or drive deck.

WORK CLAMP INSTALLATION
(See Fig. 3)

1. Remove one hex nut from work clamp.

2. Slide welding cable with ring

connector through hole in work clamp.

3. Attach ring connector to work clamp

with hex nut removed in step 1.

4

www.chpower.com

Work clamp

Welding cable

Ring connector

Hex Nut

Figure 3 - Clamp Installation

Hanger

Torch switch leads

Torch clamp knob

Torch switch
connectors

Drive deck

Torch switch
terminals

Torch

Figure 2 - Torch Installation