Quick Charge Charger Controller User Manual

Quick Charge Hardware

Advertising
background image




This Charger Controller (CC) is designed to replace existing controllers or timers in Portable and On Board ferroresonant
chargers including Lester, Mac/Motor Appliance, E-Z Go, and like chargers. The Controller can be programmed via the
Dip Switch for operation in 12, 24, 36, and 48 volt chargers. The universal mounting plate makes for easy installation in
all charger cases. The capacity of this controller is for chargers having no more than 20 amps line draw at 117 volts.


Before beginning installation, unplug charger from both AC and DC power sources.

1. Remove existing timer or controller device installed in charger.
2. Install CC using the supplied screws. Use drilling template if needed.
3. Connect the red wire to battery + .Connect on battery side of fuse and/or ammeter. Connect the black wire to battery

negative. Connect on battery side of fuse and/or ammeter.

4. Connect the AC cord and transformer primary as shown. NOTE: If your charger uses SCR’s instead of diodes

see illustration on other side.

DIP SWITCH SETTING:

ONLY ONE OF THESE SWITCHES SHOULD BE ON.
Switch 4 - 12 volt system
Switch 5 – 18 volt system
Switch 6 – 24 volt system
Switch 7 – 36 volt system
Switch 8 – 48 volt system

DO NOT CHANGE OTHER SWITCH SETTINGS.


Apply the enclosed label on the charger after cleaning the area thoroughly.

When the CC has turned the charger OFF after any charge cycle, the CC will recycle
after 60 hours, if the battery is below 2.10 VPC. Removal of DC or AC power will abort
the recycle.