Technical data, How to assemble and use – Reliable i600 User Manual

Page 8

Advertising
background image

05

TECHNICAL DATA

Working voltage: 120V
Nominal capacity of the tank: 4.5 Liters – 1.25 U.S. Gallon
Boiler power: 1 heating element 1200W
Power consumption: 16.7 amps (i600/i30), 10 amps (i600A, i600B)
Service pressure: 3,5 Bar/4 Bar
Maximum pressure: 4,5 Bar

HOW TO ASSEMBLE AND USE

1. Remove the steam station from its packing and make sure all packing has

been removed (including the protective bags). Put the station on a flat and
solid surface.

2. Your boiler is supplied with a safety cap on the blow-down valve (left side of

tank), as well as a plastic hose and fitting to secure the hose. Please remove
the safety cap and install the hose and fitting. This will allow you to follow the
proper cleaning procedure (ref. to flush the boiler tank). If there is a problem
with the blow-down valve (leaking) you can use the safety cap to prevent
water from leaking until you have the valve replaced.

3. A) i600/i30: It is recommended to put the iron on the iron pad, (supplied) as

the pad will withstand the temperature of the iron. B) i600A: Screw the nozzle
into the steam fitting and plug in the 4-pin receptacle for the electronic foot
pedal. C) i600B: Connect the steam gun or steam brush the same way using
the quick disconnect for the steam hose.

4. Insert the two-piece wand (mod. i600) or one-piece wand (mod. i600B) into

the flange on top of the boiler, tighten with the side screw and attach the
spring on the hose (mod. 600) to the coil end of the wand. Note: mod. i600A
is not supplied with a wand.

5. Before beginning any operation, make sure that the exhaust valve (9) is

closed and the drain hose is installed (ref. step #2).

6. Unscrew the safety cap (5). Fill the boiler with water to the maximum as

marked on the water level stick. Use the funnel supplied, making sure you do
not overfill the tank.

7. Insert the plug into the electrical outlet; switch on the boiler (2) and steam

buttons (1). When the two button lights come on, the steam device and
boiler are working.

8. For the i600 iron system, turn the iron plate’s temperature regulating knob

(12) to the desired temperature.