The STX 165 is designed to turn on in the Standby (SBY) Mode. The user can select an altitude at

which the STX 165 will automatically select Mode-C (ALT) Mode. This altitude is the differential

altitude from when the STX 165 was first turned on. To select an Auto On altitude:

1.

Rotate the Data knob to select the AUTO MODE C ALT page.

2.

Press the Enter Pushbutton. The Auto Alt On altitude will be blinking.

3.

Rotate the Data knob to select the desired Auto On Altitude. The altitude will change in

25 foot or 10 meter increments.

4.

Press the Enter Pushbutton

Note: The Auto On Altitude and the EFT Altitude are the differential Altitudes

from when the STX 165 is turned on. For example if the Auto On altitude is

set for 200 feet and the STX 165 is turned on at 1200 feet, the STX 165 will

automatically select ALT Mode at 1400 feet.

EFT START ALT

Note: If 0 (zero) feet or meters is selected in AUTO MODE C ALT, the STX

165 will turn on in the ALT Mode. This is generally not recommended. If

OFF is selected, the pilot will be required to select the ON or ALT Mode.

The STX 165 starts with the EFT displayed in the lower right hand corner of the display.

The user can set the EFT to begin counting at turn on or at a specified Alt above the turn on

altitude. It the EFT is set at 0, then the EFT will begin counting at turn on. To set the EFT

start altitude:

1.

Rotate the Data knob to select the EFT START ALT page.

2.

Press the Enter Pushbutton. The EFT start altitude will be blinking.

3.

Rotate the Data knob to select the desired Auto On Altitude. The altitude will change

in 25 foot or 10 meter increments.

4.

Press the Enter Pushbutton

ICING ALERT

If a SANDIA aerospace STP 78 OAT probe is installed with the STX 165 the unit will provide

an icing alert. The icing alert is a snow flake that appears in the upper right corner of the

display whenever a user preset temperature is reached. To set the Icing Alert temperature:

1.

Rotate the Data knob to select the ICING ALERT page.

2.

Press the Enter Pushbutton. The brackets will extinguish and the Temperature will

blink

3.

Rotate the Data knob until the desire Icing Alert temperature is displayed.

4.

Press the Enter Pushbutton.