INSTALLATION INSTRUCTIONS

FLUSH BOTH SUPPLY LINES BEFORE INSTALLATION

.

AFTER FLUSHING , SHUT OFF BOTH SUPPLY LINES.

MINIMUM HOLE SIZE FOR THE HANDLE TRIMS IS 1 5/8” AND MAXIMUM OF 1 3/4”

INSTALLATION INSTRUCTION

INSTALLING THE VALVE WITH THE TRIM

1. INSTALLED CORNER VALVE WITH SPLINE STEM

2- Install the valve onto the wall with 2” space
between the center of the valve inlet and the
finished wall.
Screw the handle flange with the flange washer
onto the handle bell and tighten it firmly.

3- Screw the handle bell, flange and washer onto
the all thread, press them firmly against the wall
and mark the position. Remove the handle bell,
flange and washer and cut off the excess thread.
Reinsert the handle bell, flange and washer onto
the all thread.

PAGE 02

00YY-TD _ _

center of IN port

FLANGE WASHER

finished wall

2” ~ 2

1/8

HANDLE BELL WITH FLANGE

HANDLE AND ALLEN KEY

ALL THREAD

STEM

ALL THREAD

STEM

4 - Insert the handle onto the stem. Measure the excess
between the handle bell and the handle.
Take off the handle and cut the excess stem.

5 - Reinsert the handle onto the stem. Using the Allen Key
provided, tighten the handle set screw firmly.

TEST FOR PROPER FUNCTION BEFORE CLOSING WALLS!

6 - Apply the finish trim.