TRIM INSTALLATION
- Place the shower plate on the all thread.
- Screw the Handle Bell onto the All Thread and mark the position.
Cut off the excess thread.
- Insert the Handle onto the Stem. Measure the excess between
the handle bell and the handle. Take off the handle
and cut the excess stem.
- Reinsert the handle onto the stem. Tighten the handle set screw
firmly using the Allen Key.
H
H
C
C
INSTALLATION INSTRUCTIONS
All Thread
Lock Nut
Lock Plate
HANDLE BELL
HANDLE
Trim Plate
Stem
PAGE 03
COLD
WARM
WARMER
HOT
ILLUSTRATION C
PM-280 - SERVICE VALVE (OPTIONAL)
VALVE CARTRIDGE - TE010
MECHANICAL STOP- TE013
LIMIT STOP- TE014
PM-010 - STEM
TEFLON WASHER
PM-009 - LOCK PLATE
PM-012 - LOCK NUT
PM-011 - ALL THREAD
FILTER SCREEN