1 supported elm327 programmable parameters, Supported elm327 programmable parameters, Stn1100 – ScanTool STN1100 FRPM User Manual

Page 8

Advertising
background image

STN1100

8 of 23

www.obdsol.com STN1100FRPMA

5.1 Supported ELM327 Programmable Parameters

Programmable parameters are configuration

values stored in non-volatile memory. Please refer to
the “Programmable Parameters” section of the
ELM327 datasheet for a full description of this
functionality.

All programmable parameters can be turned off

and reset to their default values by holding RESET

¯¯¯¯¯¯

input low for 5 seconds, until PC Rx LED starts
flashing rapidly. After RESET

¯¯¯¯¯¯ input is released,

device will set all factory defaults, and then perform
ATZ reset.

Programmable Parameters

PP Description

Values Default Type

00

Perform ATMA after power up or reset

00 = ON
FF = OFF

FF

(OFF)

R

01

Printing of header bytes (ATH default setting)

00 = ON
FF = OFF

FF

(OFF)

D

02

Allow long messages (ATAL default setting)

00 = ON
FF = OFF

FF

(OFF)

D

03

NO DATA timeout time (ATST default setting)
setting = value x 4.096 ms

00 to FF

32

(205 ms)

D

04

Default adaptive timing mode (ATAT setting)

00 to 02

01

D

06

OBD source (tester) address.

00 to FF

F1

R

07

Last protocol to try during automatic searches

01 to 0C

09

I

09

Character echo (ATE default setting)

00 = ON
FF = OFF

00

(ON)

R

0A

Line feed character

00 to FF

0A

R

0C

Default UART baud rate divisor
setting = 4000000 / value

02, 04,

06 to FF

68

(38.4 kbps)

P

0D

Carriage return character

00 to FF

0D

R

10

J1850 voltage settling time
setting = value x 4.096 ms

00 to FF

0D

(53 ms)

I

13

Auto search time delay between protocols 1 & 2
setting = value x 4.096 ms

00 to FF

F4

(999 ms)

I

16

Default ISO baud rate (ATIB default setting)

00 = 96

FF = 10

FF

(10.4 kbps)

R

17

ISO wakeup message rate (ATSW default setting)
setting = value x 20.48 ms

00 to FF

92

(2.99 sec)

D

18

Auto search time delay between protocols 4 & 5
setting = value x 4.096 ms

00 to FF

00

(no delay)

I

24

CAN auto formatting (ATCAF default setting)

00 = ON
FF = OFF

00

(ON)

D

25

CAN auto flow control (ATCFC default setting)

00 = ON
FF = OFF

00

(ON)

D

26

CAN filler byte (used to pad out messages)

00 to FF

00

D

29 Printing of CAN data length (DLC) when printing header bytes

(ATD0/1 default setting)

00 = ON
FF = OFF

FF

(OFF)

D

Advertising