Commands, Command format, How to use the commands – Solvline Eddy- ZB v1.0 User Manual

Page 12: Basic commands

Advertising
background image

Eddy-ZB User Guide

6.

Commands

When following commands are used to modify the values, reset command(ATSR) or rebooting by
turning off and then on the unit are require to apply the changed values.

A. Command Format

The format of all the commands are as follows.

Syntax

“AT”

+

Command

+

Values +

Carriage Return:<CR>

2Bytes

2Bytes

even Bytes

1Bytes

B. How to use the commands

Select Serial Port, then set baud rate, data, parity, stop, and flow control values.

Set as shown below.

Baud Rate : 115200

Data : 8 bit

Parity : none

Stop : 1 bit

Flow Control : none

C. Basic Commands

Commonly used commands are shown below.

AT
Command

Name

Description

Value
Range

Default
Value

AT&F

Reset
settings

Perform a factory default reset. Settings are
applied when the device reboots.
Example :

at&f

-

-

ATSR

Soft reset

Perform a software reset. Reboots the
device.
Example :

atsr

-

-