Chapter 6. Configuration via Telnet

6-4

Commands

Default

Descriptions

def port 1 interface
[RS232 / RS422 / RS485]

RS232 or
RS422

▪Eddy-S1/Pin, S1/DB9, S1/DB9-PoE
Only RS232 interface supported. Fixed. (Default: RS232)


▪Eddy-S1/Pin-C, S1/DB9-C, S1/DB9-PoE-C

RS422 or RS485 interface is supported. By software, you
can select one of these interfaces. (Default: RS422)


▪Eddy-CPU

User decides the serial interface, meaning Web or Telnet
configuration is not possible. For more information on

interface configuration, please refer to

Chapter 3.

Hardware Description

.

def port 1 socket
<port number>

4001

Set the socket number for the port. TCP Server, TCP
Broadcase, TCP Multiplex, and UDP server operation

modes make use of this port for awaiting network socket
connections.

def port 1 name

<name>

Port 1

Port alias name for convenience. 16 Characters at

maximum

def port 1 speed

[150 / 300 / 600 / 1200 /
2400 / 4800 / 9600 /

19200 / 38400 / 57600 /
115200 / 230400 / 460800

/ 921600]

9600bps Set communication speed.

def port 1 data

[5 / 6 / 7 / 8]

8

Set the number of bits in each character size.

def port 1 stop

[1 / 2]

1

Set the number of stop bits.

def port 1 parity

[none / odd / even]

none

Set parity bit check scheme.

def port 1 flow

[none / xon / rts]

none

Set the flow control scheme.

def port 1 signal

[data / modem]

data

Set the signal line checking method for the device to be

connected to the given serial port.

def port 1 remote

<IP address>

0.0.0.0

When the Operation Mode is set to TCP Client or UDP

Client, set the IP address to connect to.

def port 1 remoteport

<socket number>

4000

When the Operation Mode is set to TCP Client or UDP

Client, set the socket number to connect to.

def port 1 keepalive

<0 ~ 32767>

0

After a certain amount of time passes without any

communication after the socket connection between the
given serial port and the server is established,

automatically disconnect the socket connection.

def port 1 bypass

[Enable / Disable]

Enable

This option needs to be set when consecutive data from

the given serial port needs to be transmitted to socket at
once.

def port 1 login
[Enable / Disable]

Disable

When the Operation Mode is set to TCP Server, ask for
the username and password when the client tries to

connect. Set to 1 to enable.