5

Hardware Reset Procedure

NOTE: If video signal does not appear on the display a hardware reset can be

performed on the Transmitter Unit, Receiver Units.
1. Press the reset button for more than 3 seconds on the device using a pin point tool,

such as a ballpoint pen or a bent paper clip.

2. After 3 seconds disconnect the power adapter while holding the reset button.
3. Release the reset button, and reconnect the power adapter.

EDID Copy

EDID allows the video source to output the most ideal signal to the video display. The

“EDID Copy” function on the ST12MHDLANRX ensures that EDID is still active through

the Ethernet extender.
NOTE: If you using multiple receivers the EDID can only be copied from one unit, the

signal customized for that display will be applied to all displays connected through

additional receivers.
1. Disconnect the power cable from the Receiver.
2. Hold down the F2 button
3. Reconnect the Power while holding down the F2 button
4. Release F2 button after the power has been reconnected for 4 seconds, EDID is now

active through the Ethernet extender.

Cable Type

Multi-Mode (M-M)

Cable Diameter

(micron)

50/125 μM

Video Signal

1080p

1080i

Max. Cable Length

(meter)

800

1200

3. Install Receiver Unit

a) Position the Receiver Unit near the video display (i.e. television, projector).
b) Connect the video source to the HDMI® OUT on the Receiver Unit using an

HDMI® cable.
c) (Optional) If using the ST121HDFXA to extend an infrared (IR) device signal.

Connect the IR Receiver Cable to the IR Receiver on the Receiver Unit, and Position

the IR sensor where the remote control will point.
d) Connect the provided Receiver Unit power supply.

4. Your source video image will now appear on the remote video display.