REQUIREMENTS/SPECIFICATIONS

2-9

Other Considerations

In addition to complying with the preceding cable specifications, the
following recommendations should be followed to minimize errors and
obtain optimum performance from the network:

•

UTP cabling should be free of splices, stubs, or bridged taps.

•

Maintain a two punch-down block limit between TCU ports and wall
outlets.

•

Properly ground metal troughs, ducts, etc. carrying Token Ring
signals.

•

Avoid routing Token Ring signals near copper cables that exit a
building or are susceptible to lightning strikes and power surges.

•

UTP cables containing Token Ring signals should not be
simultaneously used for applications which may impress high voltages
(greater that 5 volts) with sharp rise or fall times. The noise coupling
from such signals could directly cause errors on the Token Ring
network.

•

Lobe lengths between TCU ports and connected devices should not
exceed 100 meters of 22 to 24 AWG wire.

•

Wherever possible, use dedicated UTP cable for Token Ring signals.

2.3 COM PORT SPECIFICATIONS

The RJ45 COM 1 and COM 2 ports (Figure 2-2) support Local
Management applications. A description of COM port applications is
listed below:

Figure 2-2. COM 1/COM 2 Ports

COM 2

COM 1

TOKEN RING HUB

WITH

LANVIEW®

SUPPORTING 100 OHM UTP CABLE

MicroMMAC-24T

DISPLAY RESET

SPEED

16M

4M