Fan direction and pattern adjustment – Harbor Freight Tools PAINT SPRAY GUN 30224 User Manual

Page 8

Advertising
background image

For technical questions, please call 1-800-444-3353;

Troubleshooting section at end of manual.

SKU 30224

Page 8

Fan Direction and Pattern Adjustment

Fan Direction

To change the direction of the fan from horizontal to vertical, loosen the Lock Ring and
turn the Air Cap (1S) 90 degrees. After the adjustment, tighten the Lock Ring by hand.
See FIGURE 3 below.

Pattern Adjustment

Warning!! Never exceed the Maximum Inlet PSI of 80 PSI.

1.

If you need to reduce the air pressure for specific areas, adjust the air compressor.

2.

To set the pattern size specific to the job, use the Pattern Control Knob (13) (see
FIGURE 1 on page 6). By turning it counterclockwise (all the way open), the pattern
will flatten. Turn the Pattern Control Knob (13) clockwise for a round pattern.
See FIGURE 4 below.

Flat/Open

Round/Closed

FIGURE 4

Note: Always make sure the Vent (48) is clear and unclogged.

FIGURE 3

Horizontal Fan

Vertical Fan

Air Cap

Lock Ring

IMPORTANT: Before using for the first time, the spray gun must be cleaned
using a solvent based thinner. If not removed, the red oil used by the
manufacturer for testing and corrosion protection may contaminate paint.
IMPORTANT: The Spray Gun must be cleaned immediately after use.
Improper cleaning is a common reason for the Spray Gun not to work.

REV 10/06

Advertising