Sftymute - safety mute, Siggen - signal generator, Argument details – ClearOne comm PSR1212 User Manual

Page 127: Appendices ~ appendix e: serial commands

Advertising
background image

121

Technical Services Group ~ 1-800-283-5936 (USA) ~ 1-801-974-3760

SFTYMUTE - Safety mute

Selects/reports the state of the safety mute. When on, the safety mute holds all

outputs on the selected unit in a muted state. It is used primarily for troubleshooting

G-Ware.

Command form: DEVICE

SFTYMUTE [Value]

Argument details

Name

Description

Device

0–7 or * to select all units

SFTYMUTE

Command

Value

0 = Off, 1 = On, 2 = Toggle, Null = Current state

Example:

#42 SFTYMUTE 1 On PSR1212 unit 2 (#42), safety mute

(

SFTYMUTE) is enabled (1).

SIGGEN - Signal Generator

This command selects/reports of the signal generator activation.

Command form: DEVICE

SIGGEN <Channel> <Group> [Type] [Amplitude]

[Frequency]

Argument details

Name

Description

Device

0–7 or * to select all units

SIGGEN

Command

Channel

See Groups and Channels, page 93

Group

I, M, L

Type

0 = Off, 1 = Pink, 2 = White, 3 = Tone, Null = Current state

Amplitude

-60 to +20 amplitude in dB; NULL for type 0

Frequency

20 to 20,000 frequency in Hz (needed only when using tone

generation)

Example:

#46 SIGGEN 1 M 2 0 On PSR1212 unit 6 (#46), the signal gen-

erator (

SIGGEN) is set to input at mic (M) channel 1 with white noise (2) at 0dB.

Appendices

~ Appendix E: Serial Commands

Advertising