Hardware installation – StarTech.com IES51000 User Manual

Page 9

Advertising
background image

Instruction Manual

6

Hardware Installation

1. Ground the device using the ground screw.
2. Power the switch from a DC power supply (input range 12 – 58V) by connecting the

positive and negative wires into the V+ and V- contacts of P1 on the terminal block

and tightening the wire clamp screws.

3. (Optional) Connect a redundant power supply connection to the contacts for P2.
4. (Optional) Connect the alarm relay as shown. By inserting the wires and set the DIP

switch of the respective Port Alarm to “ON”, the relay output alarm will detect any

port failures, and form a short circuit. The alarm relay out is “Normally Open”.

5. Connect your uplink (connection to an upstream network switch) and network

devices using RJ45 terminated Cat 5 or better network cabling.

Advertising