Troubleshooting, Indicator lights, No audio – Clarion XH7110 User Manual
Page 21

XH510/XH5410/XH7110
1
English
Owner’
s Manual
6. TROUBLESHOOTING
Indicator lights
The XH510, XH5410 and XH7110 have lights that indicate amplifier status.
Blue top
Red end-
Blue end-
LED
panel light
panel light
Meaning
On
Off
Off
Amplifier running normally
On
Alternating between
In thermal protection mode
red and blue
Slow blink Slow out-of-sync Off
Over voltage;
blink
reduce the input voltage
Quick blink Quick in-sync Off
Short circuit protection
blink
blinks,
blinks,
Off
Repeated shorts detected;
then pause then pause
remove the short circuit, wait
5 minutes for error condition
to clear; or clear condition by
removing the main power, for
example, by pulling the fuse.
No Audio
• Low or no remote turn-on voltage: check remote connections at the amplifier
and source unit.
• Blown amplifier fuse: replace with a new fast-blow fuse (same rating).
• Power wires not connected: check battery and ground wiring at the amplifier
and check the battery connections.
• Speaker leads shorted: check speaker continuity to ground; it should not show a
common ground.
• Speakers not connected or are blown: check speaker connections at the
amplifier and measure at speakers. Measure coil impedance at amplifier with