Troubleshooting, Indicator lights, No audio – Clarion XH7110 User Manual

Page 21

Advertising
background image

XH510/XH5410/XH7110

1

English

Owner’

s Manual

6. TROUBLESHOOTING

Indicator lights

The XH510, XH5410 and XH7110 have lights that indicate amplifier status.
Blue top

Red end-

Blue end-

LED

panel light

panel light

Meaning

On

Off

Off

Amplifier running normally

On

Alternating between

In thermal protection mode

red and blue

Slow blink Slow out-of-sync Off

Over voltage;

blink

reduce the input voltage

Quick blink Quick in-sync Off

Short circuit protection

blink

 blinks,

 blinks,

Off

Repeated shorts detected;

then pause then pause

remove the short circuit, wait

5 minutes for error condition

to clear; or clear condition by

removing the main power, for

example, by pulling the fuse.

No Audio

• Low or no remote turn-on voltage: check remote connections at the amplifier
and source unit.
• Blown amplifier fuse: replace with a new fast-blow fuse (same rating).
• Power wires not connected: check battery and ground wiring at the amplifier
and check the battery connections.
• Speaker leads shorted: check speaker continuity to ground; it should not show a
common ground.
• Speakers not connected or are blown: check speaker connections at the
amplifier and measure at speakers. Measure coil impedance at amplifier with
speaker wires disconnected.

Advertising