16
In case the transmitter battery is running low, a low battery warning LOBT
will be transmitted and displayed intermittently with the pressure reading
on the Vytec (Fig.2.6 d).
If the dive is started without that the Vytec and the transmitter have
been properly paired, the Vytec will indicate that no cylinder data is
available by displaying OFF (Fig. 2.6 e).
TABLE 2.1. PRESSURE TRANSMISSION RELATED DISPLAYS
Display
Indication
Figure 2.6
SETC
No code stored, set code
a
- - -
Pressure reading over 360 bar [5220 psi]
b
FAIL
Indicates pressure reading has not been
updated in more than 1 minute
c
LOBT
Indicates pressure transmitter battery voltage
d
is low. Change the transmitter battery!
OFF
Pairing has not been conducted before
e
start of dive. No cylinder data available.