Electrical connection – Creda S912E User Manual

Page 6

Advertising
background image

6

Electrical connection

This appliance conforms with the following European
Community Directives:
-

73/23/EEC of 19/02/73 (Low Voltage) and subsequent
amendments;

-

89/336/EEC of 03/05/89 (Electromagnetic
compatibility) and subsequent amendments;

-

93/68/EEC of 22/07/93 and subsequent amendments;

Warning: If the hob is fitted above a built-in oven, the hob
and the oven must be connected to the mains separately for
safety reasons and to simplify operations when it is necessary
to pull the oven out for some reason.

The electrical safety of this appliance can only be

guaranteed if the latter is correctly and efficiently
earthed, in compliance with regulations on electrical
safety. Always ensure that this vital safety measure has
been taken. If you have any doubts, call in a qualified
technician to check the electrical system thoroughly.

The manufacturer denies all responsibility for dam-

age resulting from a system which has not been
earthed correctly.

Before powering the appliance, check whether the

technical characteristics featured on the appliance data
plate correspond with those of the mains electrical sys-
tem.

Check that the current load of the mains supply and

of the power sockets is suitable for the maximum power
of the appliance, indicated on the appliance data plate.
If in doubt, contact a qualified professional.

Disconnect the appliance from the electricity supply
before all operations.

You may connect your hob to the electrical system in two
different ways:

by means of a junction box: if the appliance is

connected permanently to the mains, an omnipolar
circuit breaker
, accessible if necessary, with a mini-
mum contact opening of 3 mm should be installed.

by means of a socket conforming to the regulations

in force in the country where the appliance is fitted. It
should be accessible whenever necessary; do not use
adaptors, multiple plugs or extensions.

Important

After connecting the appliance to the flexible cable, tighten
all the screws on the terminal board. Make sure jumpers
are installed according to the type of mains system as
indicated in the table.
For example: line 1 in the table

Electrical connections

Voltage

Frequency

Fuses

Sections

230V-1+N~50 Hz

25 A*

2.5 mm²

* Application of the simultaneity coefficient in accordance with

IEC 60335-2-6 norm

5

1

2

3

4

U-bolt

connection support

Phase

Neutral

Earth

In the event of an incorrect connection:

if your appliance does not work,

check the position of the wires in the terminal board,

check that all screws are tight,

check the positioning of the jumpers.

L

N

1

2

3

4

5

Advertising