Isobus job computer : ic18 nh3, Operation, Implement parameters – TeeJet IC18 NH3 JOB COMPUTER User Manual
Page 60: Calibrations, Alarm configurations, Regulation parameters, Implement speed sensor

54
www.teejet.com
ISOBUS Job Computer : IC18 NH3
OVER
VIE
W
SE
TUP
APPENDIX
GE
TTING ST
AR
TED
OPER
ATION
Operation
Description
Factory Setting
Range/Options
User Setting
Application Rate Step
5%
1 - 20
Speed Source
CAN
CAN
Implement
Simulated
Simulated Speed
0.0 mile/h / km/h 0.0 - 99.9
Implement Parameters
Section Width
Description
Factory Setting
Range
User Setting
Section Width
118 in. / 300 cm
1 - 9999
Regulation Parameters
Description
Factory Setting
Range
User Setting
Valve Calibration, Rough
19
1 - 19
Valve Calibration, Fine
9
1 - 9
Calibrations
Implement Speed Sensor
Description
Factory Setting
Range/Options
User Setting
Pulses per Distance
0
0 - 33445
Alarm Configurations
Description
Factory Setting
Range/Options
User Setting
CAN Speed Source Timeout
4 sec
0 - 999
Active Trip Count Imformtaion
Off
Off
On
Tank Content Minimum
0 GAL (US)
0 liters
0 GAL (UK)
0 - 2641 (US)
0 - 9999
0 - 2199 (UK)