TeeJet 834 Sprayer Control L2.12 User Manual
Page 8

TECHNOLOGIES
834
Sprayer
Control
98-70019-R1 -8-
T
IP
S
PACING
Default = 50 cm
Use the
+
or
keys to adjust this value.
Once the correct spacing has have been entered,
press the key to advance to the next step.
The value shown is represented in centimeters.
P
RESSURE
R
EGULATING
M
ODE
Default = byP
The default value "byP" indicates that the pressure
regulating valve is plumbed in a bypass line. If the
default value is correct, press the key.
Use the
+
or
keys to change the
value to throttle (tHr) mode if needed.
Note: This setting must match the actual plumbed mode of the regulating valve.
Changing this setting will only reverse the polarity to the valve, it will not effect the
physical operation of the valve.
Press the key to save this parameter and to return to the normal working mode.
CAL
D
I
3 sec. = Pro
Byp
CAL
D
I
3 sec. = Pro
50