TeeJet CenterLine 230BP User Manual
Page 10

CenterLine 230BP
020-034-UK R3
9
NUMBER OF BOOM SECTIONS
The number of available boom sec-
tions is 1 to 6 or 1 to 15 depending
upon which SmartCable is detected.
Enter the number of boom sections
that are active in the system (1 to 15
sections). Use the Plus
and Minus
keys to adjust the value. Press the
Enter
key to accept the changes
and advance to the Boom Section
Widths setting.
NOTE: If a SmartCable or SDM is not connected
to the system, one Boom Width can be entered.
The Boom Width entered should be the total of
the entire boom - from 0 cm to 50 m (0 to 1969
inches). The minimum recommended width is 1
m (39 inches).
BOOM SECTION WIDTHS
Enter the width for EACH boom sec-
tion in inches (cm). Use the Plus
and Minus
keys to adjust the value.
Press the Enter
key to advance to
the next Boom Section Width setting.
When facing forward, the boom sec-
tions are ordered from left to right
along the boom. The boom section
width range is 0 cm to 50 m (0 to 1969
inches). The minimum recommended
width is 1 m (39 inches). Press the
Enter
key to accept the changes
to the last boom section and advance
to the Boom Offset Direction setting.
Individual boom section widths can
be set to different widths.
DELAY OFF
Delay Off functions as a “look ahead”
for timing the boom section valves
to turn off exactly when entering an
area that has been applied. If the
boom turns off too soon when enter-
ing an applied area, decrease the
Delay Off setting. If the boom turns
off too late when entering an applied
area, increase the Delay Off setting.
The delay time is established in sec-
onds and tenths of seconds. Use the
Plus
and Minus
keys to adjust
the value. The Delay Off Time range
is 0.0 - 10.0 seconds. Press the En-
ter
key to accept the changes and
advance to the Overlap setting.
OVERLAP
Overlap determines the amount of
overlap that is allowed when the
boom sections are turned on and off.
Select the percent of overlap from
three pre-determined settings (0%,
50%, and 100%) using the Plus
and Minus
keys. Press the Enter
key to accept the changes and ad-
vance to the Number of Boom Sec-
tions setting.
5