Connections in the pull away plug, How to mount the speed transmitter – TeeJet LH 1200S User Manual
Page 4
Advertising

4
LH A
GRO
CONNECTIONS IN THE PULL AWAY PLUG
(Seen from the maunting side)
Note: The special 7-poled plug allows connection of many different types of
sensors on machines and implements (eg. count, flow and RPM).
See the different possibilitiess on the last page.
Signals in the 7-poled plug:
Pin 1
N/A
Pin 2
Flow or RPM
Pin 3
N/A
Pin 4
Speed transmitter
Pin 5
0 V (negative)
Pin 6
12 V (positive)
Pin 7
Override sensor
HOW TO MOUNT THE SPEED TRANSMITTER
Note:
Mount 2 magnets on the navel (180°
apart), use the wheel bolts for precision.
The yellow marks (south) must face the
sensor.
You can glue the magnets. The gap
between the magnets and sensor must
not exceed 5 mm.
Take care when tightening the sensor
(tighten lightly).
Advertising