7 repairs, 8 technical data – TeeJet LH Sprimas User Manual
Page 12

LH S
PRIMAS OPERATORS MANUAL
12
LH A
GRO
7 REPAIRS
Repairs should only be carried out by trained personnel.
Note!
Moisture in the electronics housing can lead to incorrect operation of the system.
8 TECHNICAL DATA
Number of measuring channels:
10
Measurement range:
50 - 800 ml/min
Measuring container volume:
67 ml
Fill height measurement using ultra
sound sensor:
Resolution +/- 0,07 mm
Maximum working width:
36 Meter
Travel sensor:
2500 pulses per revolution
Sensor wheel circumference:
Approx. 200 mm
Test time per m incl. Travel & wait time
At 100 ml/min per channel:
15 - 20 seconds
At 400 ml/min per channel:
15 - 20 seconds
Return speed:
0,4 m/s
Battery capacity:
44 Ah
Consumption for 10 metres test:
< 0,5 Ah
Surrounding temperature
Testing:
0°C - +30°C
Storage:
-10°C - +40°C
CE mark:
EMV/VDI recommendation 4500