Calculation Chart Instructions

Wind Zone II

12’ x 18’ Shed

Example:

Wind Zone II chart shows 12’ x 18’ building:

1. Looking in 12’ column - Use lowest value in the 12’ column for the

number of anchors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2. Looking in 18’ column - find the corresponding width of 12’ to

obtain the number of anchors for the 18’ side . . . . . . . . . . . . . . . . . . 5

(if building width exceeds the widths shown in the Building Width

column, use the lowest number of anchors in the corresponding

Building Width column)

*

NOTE: Anchors at the corners shall be counted only once in

the quantity required for each side or face of building.

3. Total Anchors needed per 12’ x 18’ shed in Wind Zone II. . . . . . . . . . . . .12