1. Check that the cylinder valve is closed by turning the cylinder

knob clockwise to a full stop.

2. Check that all the grill burner knobs are in the off position.

3. Remove the protective caps from the cylinder valve and cou-

pling nut. NOTE: The coupling nut connects to the large outside

threads on the valve outlet.

4. Hold the regulator in one hand and insert the nipple into the

valve outlet. Be sure the nipple is centered in the valve outlet.

Hand-tighten the coupling nut, taking care not to cross-thread

the connection (see Fig. 15).

5. Turn the coupling nut clockwise, tighten to a full stop.

If you cannot complete the final connection, disconnect the reg-

ulator and repeat steps 4 through 6. If you are still unable to

complete the connection, DO NOT use this valve and regulator!

6. Check that the hose has no kinks or sharp bends and clears

areas that will become hot during use. Never put strain on the

hose where it joins a fitting.

7. BEFORE lighting grill, check all connections for leaks using the

procedure as shown in Fig. 16 on pg. 28.

WARNING

This procedure MUST be performed OUTDOORS only! Be

sure L.P. cylinder valve is closed. Attach to Grill. Read and

follow directions on the cylinder and fuel hose safety tags.

CAUTION

In the connection process, the grill side of the connection will

seal on the back-check in the valve, resulting in a slight

resistance. The connection requires about one-half to three-

quarters additional turn to complete the connection. To dis-

connect, turn counterclockwise. Tighten by hand only. DO

NOT use tools.

DANGER

T

O

P

REVENT

F

IRE OR

E

XPLOSION

H

AZARD

:

• NO SMOKING. DO NOT use or permit sources of ignition

in the area while doing a leak test.

• Perform leak tests outdoors only.

• NEVER perform a leak test with fire or flame.

Connecting Type 1 L.P. Gas Cylinders

Leak Testing

15

Leak Testing

(cont.)

• If you detect a leak:

1. Turn off the fuel supply. Push in and turn on control knobs

to release pressure in hose, then turn the control knobs back

to off.

2. Wash off soapy solutions with cold water and towel dry.

3. Stop a leak by tightening the loose joint, or by replacing the

faulty part with a replacement part recommended by Coleman.

DO NOT attempt to repair the cylinder valve if it should

become damaged; the cylinder MUST be replaced.

4. If you are unable to stop a leak, shut off the gas supply at the

cylinder valve. Remove the cylinder from the grill. Call a gas

appliance serviceman or L.P. gas dealer. DO NOT use grill

until the leak is corrected.

• When to test for leaks:

1. Perform a leak test each time the gas supply cylinder is

connected to the regulator. Leak test anytime a part of

the gas system is replaced.

2. Perform a leak test at least once each year whether the L.P.

gas supply cylinder has been disconnected or not.

3. Have a dealer check the cylinder for deterioration after 12

years, according to DOT regulations. Immediately replace

cylinder if any deterioration is found.

16

How to Check for Leaks

1. Make a soapy solution of equal parts mild liquid dishwashing

detergent and water.

2. Turn off all burner control knobs.

3. Turn on fuel supply. Turn cylinder valve knob counterclock-

wise (right to left) one rotation.

4. Apply soap solution to connections indicated with arrows in

Fig. 16. If bubbles appear at these areas, a leak is indicated.