Tii 95S-2-00-0 User Manual

Page 2

Advertising
background image

Wiring

1. The receive and transmit pairs are connected

to the Bridge. Customer has the option of
installing a #10 Master lock around the
customer lock hasp (see figure 1).

2. Do not strip wire insulation from wires to be

terminated to Bridge.

3. Dress terminating wires (to protector) over NID

divider (see figure 2).

4. Open customer security cover on Bridge.

5. Lift both Bridge rockers to the full up position

as shown (see figure 3).

6. Dress wires around security cover.

7. Hold the customer receive pair wires between

thumb and index finger (approx 1/8”
separation between wires).

NOTE: Wires should be aligned to the
corresponding holes.

8. Insert wires into wire guides at the same time

until they bottom out.

9. While holding wires in wire guides, terminate

rocker with thumb (lower rocker all the way).

10. Terminate transmit pair to rocker.

11. Assure both rockers are in the down position

and close customer security cover.

Figure 3

Signal Testing

1.

Open customer security cover.

2.

Using a portable data test set, insert dataline RJ-45 plug
into customer test jack (see figure 3).

3.

Verify that the portable data test set is able to
communicate with central office.