Wiring

1. Insert the grounding conductor, the customer

side cable and the Telco side cable through
the grommet in the base of the protector.

2. Terminate one end of the grounding conductor

(No. 6 AWG) on the ground stud / binding post
and the other end to an appropriate ground
source (See Figure 3).

3. Terminate the Telco Side cable in between the

bottom set of washer and bottom nut of the
appropriate stud (one conductor to Tip and
one to Ring) and tighten down (See Figure 3).

4. Terminate the Customer Side cable under the

top set of washers and the top nut of the
appropriate stud (one conductor to Tip and
one to Ring) and tighten down. (See Figure 3).

5. Loop back unused station wire conductors and

coil around the station wire jacket or store in
such a manner as to prevent them from
coming in contact with protector terminals or
bare wires.

Figure 3

Customer Side Cable

Telco Side Cable