tii P/N: 92224401

the green MTA power LED provided on the
line will start to blink.

3.6 Disconnect the customer premise wiring

from the Telephone Network Interface
Device (NID). Straighten the ends of the
wires, cut kinked and stripped ends. Lift the
Green/Red rocker to full up position. Insert
wires into the Customer wire rocker holes.
While assuring that wires are fully inserted
lower the rocker to fully seated position (See
Fig 3).

3.7 Connect the Telco Service using a wire pair

from the Telephone NID to the rocker
labeled TEL (orange). Follow procedure
described above for the wire pair termination
(See Figs 2 & 3).

3.8 To keep wire pairs organized, route them

through the molded wire looms. (See Fig. 2)








4. Installation (Line 2)
4.1 Follow steps 3.4 to 3.8 to connect Line 2

through the SVM-2.

5 RESET

IMPORTANT: This unit MUST be reset during
initial installation. Follow these instructions to
reset the unit.

5.1 Confirm that the power is connected to the

MTA (Blue) rocker of SVM-2 by observing
green LED blinking.

5.2

Gently push the reset button once with a
blunt object to ensure the service to the
customer is from the Telco Service Provider
(See Figure 4).

NOTE:

THE RESET SWITCH IS DISABLED DURING

RINGING VOLTAGE PRESENCE AND TEN

SECONDS AFTER THE LAST RINGING

VOLTAGE.

CAUTION:

TO AVOID PERMANENT DAMAGE TO RESET

BUTTON DO NOT USE EXCESSIVE FORCE

OR A POINTED OBJECT TO ACTIVATE THE

RESET BUTTON.

Figure 2

Terminated rocker

Wire loom

Full Up Position

Figure 4

* RESET BUTTON

’S

CUSTOMER WIRING (L1)

TEST POINTS

MTA LED’S

CUSTOMER WIRING (L2)

Figure 3

DIGITAL VOICE

SERVICE WIRES (L2)

TELCO WIRES (L2)

TELCO WIRES

TELCO WIRES (L1)

TELCO WIRES

DIGITAL VOICE

SERVICE WIRES (L1)