TII P/N: 92222401

3.7 RESET

3.7.1 Confirm that the power is connected to

the MTA RJ-11 receptacle of the SVWJ.

3.7.2 Gently push the reset button once with

a blunt object to ensure the service to the
customer is from the Telco Service Provider
(See Figure 1).

NOTE:

THE RESET SWITCH IS DISABLED DURING

RINGING VOLTAGE PRESENCE AND TEN

SECONDS AFTER THE LAST RINGING

VOLTAGE.

CAUTION:

TO AVOID PERMANENT DAMAGE TO

RESET BUTTON DO NOT USE

EXCESSIVE FORCE OR A POINTED
OBJECT TO ACTIVATE THE RESET

BUTTON.

3.8 Dress the wires properly inside the
junction box and secure the SVWJ to the
junction box using the supplied #6 oval head

screw’s (See Figure 2).

3.9 Existing Construction Installation

3.9.1

Cut drywall 2” W x 3.5” L in the location

where the SVWJ is going to be mounted. Prior
to cutting hole confirm that there are no
obstructions behind wall.

3.9.2 After drywall has been cut, install the

wall mounting plate. Bend the two mounting tabs
behind the drywall and secure the mounting
plate with the supplied drywall screws (See
Figure 3). Align the mounting tab slots while
tightening the screws.

3.9.3 Dress the wires properly inside the wall
mounting plate and secure the SVWJ to the
junction box using the supplied #6 oval head

screw’s (See Figure 3).

#6 Drywall Screws

#6 Oval Head Machine Screws

Figure 3

Wall Mounting Plate

Existing Junction Box

#6 Oval Head Machine Screws

Figure 2