(C68)

(When the control output function is set to CH ON)

C - O U T 0 1 ->

C H O N

(C67) Scene memory bank number selection

C - O U T 0 1 - L D S C E N E

0 1

(C69) Input/Output channel number selection

C - O U T 0 1 - C H O N ->

I N 1

(C66)

(When the control output function is set to SCENE)

C - O U T 0 1 ->

L D S C E N E

[When the function is set to SCENE]

Provides a Level output when a Scene memory is recalled.
Assigning a function to this terminal overwrites the previously set function on it if there is.

Select the Scene memory bank number that causes the selected control output terminal to provide a Level
output when the Scene memory is recalled.

01 -32 (default: 01)

Setting Range

[When the function is set to CH ON]

Provides a Level output when the input or output channel becomes on.
Assigning a function to this terminal overwrites the previously set function on it if there is.

Select the input or output channel number that causes the selected control output terminal to provide a Level
output when the channel becomes on.

IN1 – 8, OUT1 – 2, Max. OUT8 when T-001Ts are used (default: IN1)

Setting Range