6.6. Systems Combining the FS-7000RF, FS-7000RM, and FS-7010RM
When using the FS-7000RM, add the FS-7000RF and perform the wiring shown below.
Then, connect the FS-7000RF and the FS-7000RM. When expanding the FS-7000RM's Zone Selector Keys,
connect the FS-7010RM to the FS-7000RM.
[Notes]
• For the FS-7000RF's RF Zone Control Terminal 3 and subsequent terminals, make connections in such a
way that Terminal 3 is connected to the second FS-7010CP, Terminal 4 to the third FS-7010CP, and
Terminal 5 to a fourth FS-7010CP.
• If the FS-7000GM is to be connected to the FS-7000CP, the FS-7000RF's RF Zone Control Terminal will
need to be connected to a different terminal (see page 47 for details).
[Wiring Diagram]
The figure shows only the wiring related to the FS-7000RF.
For the wiring of other models, refer to the relevant system wiring diagrams, such as those for basic
configuration and zone expansion.
FS-7000PS
FS-7000CP
FS-7010CP
FS-7000RF
230 V AC
DC POWER OUT
DC POWER IN
DC POWER IN
DC POWER IN
RF IN
RF CONT
RF OUT
RF CONT
RF ZONE CONT
RF ZONE CONT 2
RF ZONE CONT 1
RF ZONE CONT
: Supplied cables
: Cables prepared separately
See page 64; Table for Cables.