Digital speaker processor dp-sp3, Toa corporation, Command list – Toa DP-SP3 Protocol User Manual
Page 11

Digital speaker processor DP-SP3
TOA Corporation
11/14
■
Command List
Function
Command Code
Gain (position)
91H, 03H, <Channel Attribute>, <Channel Number>, <Position>
Gain (step)
91H, 03H, <Channel Attribute>, <Channel Number>, <Step>
Matrix Assignment
94H, 03H, <Input Channel Number>, <Output Channel Number>,
<ON/OFF>
Matrix Crosspoint Gain
95H, 03H, <Input Channel Number>, <Output Channel Number>,
<Value>
Attenuator (position)
96H, 02H, <Channel Number>, <Position>
Attenuator (step)
96H, 02H, <Channel Number>, <Step>
Mute
97H, 02H, <Channel Number>, <ON/OFF>
Preset Memory Load
F1H, 02H, 00H, <Preset Number>
Preset Memory Store
F3H, 08H, 00H, <Preset Number>, <Year>, <Month>, <Day>, <Hour>,
<Minute>, <Second>
Level Meter Status Notification Interval
F2H, 02H, 00H, <Notify Interval>
Auto Status Notification Start/Stop
F2H, 02H, 01H, <ON/OFF>
Status (Gain)
F0H, 03H, 11H, <Channel Attribute>, <Channel Number>
Status (Matrix Assignment)
F0H, 03H, 14H, <Input Channel Number>, < Output Channel Number>
Status (Matrix Crosspoint Gain)
F0H, 03H, 15H, <Input Channel Number>, <Output Channel Number>
Status(Preset)
F0H, 02H, 71H, 00H
Status (Contact Input make/break Status)
F0H, 03H, 42H, 00H, <Contact Number>
DP-SP3 Connection establishment status
DFH, 01H, 01H
Contact Input Make/Break Status
E6H, 04H, 02H, <Contact I/O>, <Contact Number>, <Make/Break>
Level Meter Status Format
E6H, 04H, 00H, <Channel Attribute>, <Channel Number>, <Level>