Toa SX-2000 Series Installation User Manual

Page 25

Advertising
background image

25

3

4

Function

LED On

LED Off

4. Not used

3. RESET input

Resetting

Normal

1

2

3

4

Function

LED On/Flashing

LED Off

2. B connection confirmation

Connected

Unconnected

1. B operation in progress

indication

Operating

Not operating

4. A connection confirmation

Connected

Unconnected

3. A operation in progress

indication

Operating

Not operating

SX-2000AO

1

2

Function

LED On

LED Off

1. Not used
2. OUT connection confirmation Connected Unconnected

50. Analog Link Output Terminal

[ANALOg LINK OUT]

connect this terminal to the analog link input

terminal of the SX-2000AI, SX-2100AI, SX-

2000Ao, or SX-2100Ao.

51. Analog Link Input Terminal

[ANALOg LINK IN]

connect this terminal to the analog link output

terminal of the SX-2000Sm, SX-2000AI, SX-

2100AI, SX-2000Ao, or SX-2100Ao.

52. SX Link Terminals [SX LINK A/B]

use switching hubs to connect between the SX

link terminals of the SX-2000Sm, SX-2000AI, SX-

2100AI, SX-2000Ao, and SX-2100Ao. connect

each of the SX links A and B to the same

switching hub*, or to different switching hubs* that

have been connected in star configuration.
Notes

• Be sure to connect both terminals of A and B.

• After connection completion, press the Reset

key to reactivate the SX-2000Ao.

* contact your toA dealer for more information

on switching hubs.

53. MAC Address

mAc address to be used for SX link connection.