Central unit TS-910

Expansion unit TS-918

Expansion unit TS-918

Expansion unit TS-918

Coaxial cable

Distributor YW-1022

(2 branches) or

YW-1024 (4 branches)

Expansion unit TS-918

Bridge unit

TS-919B1/919B4

Wired Conference unit

TS-911/912/811/812

1

TS-919B1

EXPANSION

BRIDGE

BRIDGE UNIT

LAN cable (CAT-5)

1

TS-919B1

EXPANSION

BRIDGE

BRIDGE UNIT

LAN cable (CAT-5)

BRIDGE UNIT

EXPANSION

TS-919B4

BRIDGE

1

2

3

4

Communication cable

connection terminal

(Expansion unit side)

Conference

unit connection

terminal

Conference unit connection

terminal 1 – 4

Communication cable

connectionterminal

(Bridge unit side)

Bridge unit

(1-Conference unit connection type)

TS-919B1

Bridge unit

(4-Conference unit connection type)

TS-919B4

Communication cable

connection terminal

(Expansion unit side)

Communication cable

connection terminal

(Bridge unit side)

• A system may have Expansion units that both pass through and do not pass through the Distributor.

7.2. Expansion unit, Bridge Unit, and Wired Conference Unit Connections

When connecting the Expansion unit to the

Wired Conference Unit, the Bridge unit must

be installed between the two.

The Expansion unit is equipped with 3 Bridge unit connection terminals. When Bridge units are connected to

them, up to 8 Wired Conference units can be connected for each terminal, and up to 24 units per Expansion

unit. Two types of Bridge units are available, the 1-Conference unit connection type and the 4-Conference unit

connection type.

The number of connection terminals for each type is as follows.

[Number of Bridge unit’s connection terminals]

Model No. Communication cable connection

terminal (Expansion unit side)

Conference unit connection

terminal*

1

Communication cable connection

terminal (Bridge unit side)

TS-919B1

1

1

1*

2

TS-919B4

1

4

1*

3

*

1

One Wired Conference unit can be connected to each Conference unit connection terminal.

*

2

Either a TS-919B1 or TS-919B4 Bridge unit can be connected. In an exceptional case where 7 Bridge units

of 1-Conference unit connection type are connected to one of the Expansion unit’s Bridge unit connection

terminals, connect the 8th Conference unit, if needed, to the last-connected 1-Conference unit type Bridge

unit’s communication cable connection terminal (Bridge unit side).

*

3

Can be connected to a TS-919B1 or TS-919B4 Bridge unit. However, the Wired Conference unit cannot be

connected.