5.10. Input Sensitivity Setting

Performs input sensitivity setting of Input channel. 9000M2 Series Amplifier responds with
the same data as that received. Input sensitivity setting is enabled only for the channel on
which the D-001T or AN-001T is used.

Note: Command cannot be received during power off.

ACH, 02H, <Channel Number>, <Value>

<Channel Number>

00H - 07H (Input channel 1 - 8)


<Value >

INPUT SENSITIVITY TABLE

Value

Value

HEX

DEC

Sense

(dB)

HEX

DEC

Sense

(dB)

00H 0

-10 05H 5

-42

01H 1

-18 06H 6

-48

02H 2

-24 07H 7

-54

03H 3

-30 08H 8

-60

04H 4

-36



Example: Setting the input sensitivity of Input Channel 5 to –24 dB.

ACH, 02H, 04H, 02H